There is no single right size. Many UK homes end up somewhere between roughly 3 kWp and 6 kWp, but the best figure depends on how much electricity you use during the day, your usable roof, shading, inverter and network limits, and any battery, EV or heat pump you plan to add. Annual consumption is a starting point, not the answer.
Because a solar system produces power when the sun shines, not when you need it. Two homes can both use 4,000 kWh a year and need very different systems.
Annual use tells you the total, but four other things decide the right size:
kWp is the size of the array, and kWh is the energy it produces or you use over time. Mixing them up is the most common mistake in solar quotes.
kWp (kilowatt peak) is the DC rating of the panels under standard test conditions. Ten 400 W panels make a 4 kWp array. kWh (kilowatt hour) is energy, the unit on your bill. kW is instantaneous power, such as an inverter's AC output.
As a rough guide, a well-placed, unshaded south-facing array in South Wales might generate in the region of 800 to 950 kWh per kWp per year. So 4 kWp might produce around 3,200 to 3,800 kWh, depending on the roof and the year's weather. These are indicative figures, and a survey gives a better one for your roof.
Yes, for most households it matters more. Solar saves you the most money when you use the power as it is generated.
If nobody is home between 9am and 5pm, much of a typical array's output will be exported. If someone works from home, or you run a dishwasher, washing machine and immersion heater on timers, you use more of it directly. Exported electricity earns whatever your Smart Export Guarantee tariff pays, which varies by supplier and is usually well below what you pay to import.
A smart meter's half-hourly data, or just a realistic description of your week, tells us far more than the yearly total.
They set how many panels fit and how much each produces. A large roof that is shaded or north-facing may support a smaller useful system than a modest south-facing one.
A south-facing roof at a pitch of around 30 to 40 degrees is generally the best for annual output. East- and west-facing roofs typically produce somewhat less per kWp, often in the region of 10 to 20% less. They spread generation across the morning and late afternoon, which can suit households with early and evening demand. A split east/west array often fits more panels in total than a single south slope.
Pitch matters less than people expect, but very shallow or very steep roofs lose some output. Flat roofs can use tilted frames, which take more space and add wind loading to the design.
Chimneys, dormers, trees and neighbouring buildings can cut output, particularly in winter when the sun is low. Panel-level optimisers or microinverters can help with partial shade. Heavy all-day shading on a slope is often a reason to leave that slope empty.
As a rule of thumb, allow roughly 5 m² of clear roof per kWp with typical modern panels. The table assumes 400 W panels of about 1.95 m² each, and an unshaded south-facing roof at an assumed 850 kWh per kWp per year.
| Array size | Panels (400 W) | Approx. roof area | Indicative annual output |
|---|---|---|---|
| 2.0 kWp | 5 | about 10 m² | about 1,700 kWh |
| 3.2 kWp | 8 | about 16 m² | about 2,700 kWh |
| 4.0 kWp | 10 | about 20 m² | about 3,400 kWh |
| 4.8 kWp | 12 | about 23 m² | about 4,100 kWh |
| 6.0 kWp | 15 | about 29 m² | about 5,100 kWh |
Real layouts lose space to roof edges, hips, vents, rooflights and fire-safety clearances. Panel sizes vary by model, so treat these as ballpark numbers.
The array's kWp can exceed the inverter's AC rating, and this is normal practice. Panels rarely produce their full rated power in the UK because of cloud, angle and temperature, so a smaller inverter can handle the output nearly all of the time.
For example, a 5 kWp array on a 3.68 kW inverter has a DC-to-AC ratio of about 1.36. On the few brightest hours of the year, the inverter caps output (known as clipping) and a little energy is lost. Over a year that loss is typically small, but it depends on orientation and ratio. East/west arrays tolerate more oversizing because their output peaks are flatter. We model the clipping loss before recommending a ratio.
They can limit the inverter output or the amount you may export, so you cannot assume any size will be accepted. Your local network has finite capacity.
On a single-phase home, inverters up to 3.68 kW (16 A) can usually be installed under a simple notification process (G98). Larger systems normally need an application to the network operator first (G99). Where the local network is constrained, the operator may approve the system only with an export limit, or may require network work. An export-limited system can still have a larger array, because it uses the extra generation on site or charges a battery.
They change when and how much electricity you use, so they can justify a larger array or a different design. Plan for them now if they are likely within a few years.
For a heat pump home, a bigger annual bill does not mean solar can cover it. The timing matters as much as the total.
These examples show the reasoning, not a recommended size for any usage band. Every assumption is stated. Your own roof and habits will change the answer.
Assume a couple who are out during the day, with gas heating and a south-facing roof at 850 kWh per kWp. A 2 kWp array would produce about 1,700 kWh and a 3.2 kWp array about 2,700 kWh. The larger one roughly matches annual use, but most output arrives while nobody is home, so a large share would be exported. A smaller array may suit this home, though fixed installation costs mean a larger one can still be reasonable value. We would price both.
Assume a family where one adult works from home, with a 4 kWp south-facing array producing about 3,400 kWh. If 35% is used on site (about 1,190 kWh) at an assumed 27p per kWh import price, that is about £321. The remaining 2,210 kWh exported at an assumed 10p per kWh gives about £221. That is roughly £540 a year before any battery. At 25% or 45% self-use the result changes, and tariffs will too. This is an illustration, not a prediction.
Assume a household with someone at home in the day, and a roof split east and west that fits 15 panels (6 kWp). At an assumed 720 kWh per kWp, output is about 4,300 kWh. A 5 kW inverter gives a DC-to-AC ratio of 1.2, so clipping losses should be small. The spread of output across the day suits a household with morning and late-afternoon demand.
Assume a large home with a heat pump and an EV, and roof space for about 8 kWp (20 panels, roughly 39 m²). At 850 kWh per kWp that is about 6,800 kWh, but much of it falls in summer when heating demand is low. Solar would offset a useful part of the total but not most of the winter load. This home would also need a three-phase supply check and likely a G99 application, and a battery and solar-aware EV charging would be worth modelling.
Tell us roughly what you use and what your roof looks like. We reply within one working day, with no obligation.
We size a system from a survey, not from a rule of thumb or a guess. A quote based on your annual kWh alone would miss most of what decides the right size.
On a survey we typically check:
Heliaxis is an MCS-certified installer working across South Wales. We give you a written quote after the survey, with the assumptions shown, so you can see how we reached the size. If a smaller system, or no solar, is the better fit, we will say so. You can also try the solar estimator for a first idea, or book a survey when you are ready.
No. A larger array produces more, but if you cannot use the extra on site it is exported at a lower rate. Roof space, network limits and cost per extra panel all matter, so we compare a few sizes.
There is no fixed number, because it depends on your roof, orientation and how much you use during the day. On an unshaded south-facing roof, about 10 panels at 400 W (4 kWp) might generate roughly 3,400 kWh, but that is an indicative figure. It does not mean 10 panels suit every 4,000 kWh home.
Yes, and it is common. Panels seldom reach their full rated output in the UK, so a smaller inverter loses only a little energy at the brightest moments. We model the loss before choosing a ratio.
Not necessarily. A battery raises the share of solar you use yourself, but it adds cost and may be harder to justify on a low electricity bill. It is worth considering if you are out in the day and use most power in the evening.
If you are likely to get one within a few years, it is worth planning for it now. We can leave room on the roof and check that the inverter, supply and network application suit the future load.
Yes. Each slope typically produces less per kWp than a south-facing one, but generation is spread across the day, which can suit your usage. A split roof can also hold more panels in total.
Roughly 5 m² of clear roof per kWp is a sensible rule of thumb. A 4 kWp system therefore needs about 20 m², before allowing for obstructions and edge clearances.
If you would like a size worked out for your home, request a free, no-obligation quote or book a call and we will talk it through.
It takes about a minute. No obligation.
No obligation and no pushy sales — we’ll simply arrange a free survey.
A solar system sized around your daytime use, roof and plans, not just your annual bill.
Sites that use most of their power in the daytime can often make good use of solar.